Welcome to Shaanxi Xite Cable Co., Ltd.
Home / Products / Power Cable / Low Voltage Power Cable / 1000 volts Low Voltage 3 Core 120mm 150mm 185mm 95mm 70mm Copper XLPE Insulated PVC Sheathed N2XY Armoured Underground Power Cable

Random Products

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

1000 volts Low Voltage 3 Core 120mm 150mm 185mm 95mm 70mm Copper XLPE Insulated PVC Sheathed N2XY Armoured Underground Power Cable

0.6/1KV Copper/Aluminum conductor electrical power cable with XLPE or PVC insulation, PVC or PE outer sheath, STA steel tape or SWA steel wire armoured or non armoured low voltage power cable/kable
Availability:
  • YJV,YJV22,YJV32,VV,VV22,VV32

  • XITE

  • 8544492100

  • Copper or Aluminum

  • 600/1000V

  • XLPE or PVC

  • PVC or PE or LSZH

  • SWA ,STA or Unarmored

  • Flame Retardant, Antiflaming, Fire resistance, LSZH

1000 volts Low Voltage 3 Core 120mm 150mm 185mm 95mm 70mm Copper XLPE Insulated PVC Sheathed N2XY Armoured Underground Power Cable


pulling low voltage cable-XITE low voltage underground wire-XITE

low voltage outdoor lighting extension cable Introduction:

Power cable: Copper or Aluminum conductor electric power cable with XLPE or PVC insulation, PVC or PE outer sheath, STA steel tape armoured or non armoured electrical power cable/kable

Type:YJV, YJV22,YJV23,YJV32, YJLV, YJLV22,YJLV32

Core number: 3 core

Production Range : 1.5mm2, 2.5mm2, 4mm2, 6mm, 10mm2,16mm2, 25 mm2 , 35 mm2 , 50 mm2 , 70 mm2 , 95 mm2 ,120 mm2 ,150 mm2 ,185 mm2 , 240 mm2 300 mm2 

Related Voltage: 0.6/1kV

NO.of cores×section (mm²) Permissible   A mpacity                                                              (A) Reference overall   diameter of cable(mm) Reference   weight of cable(kg/km)
YJV YJV22

Cu Cu
Cu
In air In ground In air In ground Unarmoured Armoured YJV YJV22
3x1.5

21 26
13.3
268
3x2.5 28 37 28 34 11 14.2 171 318
3x4 37 48 37 45 12 15.2 225 379
3x6 47 61 46 57 13.1 16.3 296 463
3x10 64 82 63 77 15.3 18.6 440 628
3x16 85 107 83 100 17.5 20.7 638 851
3x25 115 138 112 131 21 24.2 954 1209
3x35 140 165 137 158 23.1 26.4 1266 1546
3x50 168 198 163 187 23.4 26.8 1614 1908
3x70 213 242 211 233 27.4 32 2246 2874
3x95 263 290 255 277 30.6 35.4 2975 3685
3x120 307 330 298 317 34 38.8 3776 4560
3x150 357 371 348 358 38.6 43.4 4682 5570
3x185 415 418 403 403 43.3 48.5 5802 6837
3x240 498 485 480 468 48.1 53.5 7437 8606
3x300 575 548 549 531 52.2 57.6 9313 10577

low voltage underground wire Application:

This product is suitable for power transmission and distribution under AC rated voltage 0.6/1kv and working frequency 50Hz lines.


Low Voltage power cable is used to transmit and distribute power in power transmission and distribution system of 1kV. It is generally applied to the fields including power, mines, construction,  metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.


3 core low voltage cable advantages:

Low voltage power cable have higher long-term working temperature and greater current rating, and under the condition of the same environment, XLPE cable may be reduced size (normal cross section) 1 or 2 class in comparison with PVC cable. These are not only improving the quality and properties of products, but also reduce cables' production cost.


low voltage armoured cable Using Feature:

1. Cable conductor allowed working temperature doesn't exceed 70 ºC in a long term

2. When the short circuit happened (the longest duration is no more than 5 seconds), the highest temperature of the cable conductor does not exceed 160 ºC.

3. The environment temperature should not below 0 ºC when cable laying, To warm up first when the temperature lower than 0 ºC .

4. The minimum bending radius of the multicore-non armoured cable shall not be less than 12 times of the outer diameter of cables, and the minimum bending radius of the mutilcore-armored cables shall not be less than 15 times of the outer diameter of cables. The minimum bending radius of the single core armoured cable shall not be less than 15 times of the outer diameter of cable, and the minimum bending radius of the single core -non armoured cable shall not be less than 20 times of the outer diameter of cable

5. Structure parameter of rated voltage 0.6/1KV XLPE insulated power cable


Please note that the above these cables could make to Antiflaming power cable, Fire resistance power cable, LSZH power cable in rated voltage 0.6/1 KV, PVC or XLPE insulated, PVC outer sheath.


Previous: 
Next: 
Get in touch
Xite Cable will be dedicated to provide the best service, continue to progress and to become a model for the industry and excellent brand.

Quick Links

Get in touch

     (+86)-029-86198018 / (+86)-138-9194-3607

   sales@xitecable.com 

     Workshop B5, Jingfa Chuangxin Industry Park, No. 36, Jingwei Middle Road, Jingwei New City, ETDZ, Xi'an Shaanxi, P.R.China.

©  2021 Shaanxi Xite Cable Co.,Ltd  All rights reserved. 丨 Sitemap.