Availability:
  • DJYPVP,DJYPVP22,DJYP1VP1,DJYP1VP1-22,DJYP2VP2,DJYP2VP2-22,DJYJPVP,DJYJPVP22,DJYJP1VP1,DJYJP1VP1-22,DJYJP2VP2,DJYJP2VP2-22

  • XITE

  • 8544492100

  • Copper or tinned copper

  • 300/500V

  • XLPE or PVC or PE

  • PVC or FR or LSZH

  • Unarmored

  • Flame Retardant, Antiflaming, Fire resistance, LSZH

China 2X2X2.5mm2 XLPE Insulated Individual Screen Overall Shield ISOS LSZH Sheathed fire resistant 14 awg Twisted Pairs Instrumentation Cable


overall screen cable-XITE different types of instrument cables-XITE

2 pair instrument cable Introduction:

Nominal Size: 0.5mm2, 0.75mm2, 1.0mm2, 1.5mm2, 2.5mm2

Core: 2 core, 3 core

Pair: 1 pair, 2 pairs,3 pairs ,4 pairs ,5 pairs ,7 pairs ,8 pairs ,10 pairs ,12 pairs ,14 pairs,16 pairs ,19 pairs ,24 pairs ,27 pairs ,30 pairs, 37 pairs

Specification:1*2*2.5mm2, 2*2*2.5mm2, 3*2*2.5mm2, 4*2*2.5mm2, 5*2*2.5mm2, 7*2*2.5mm2, 8*2*2.5mm2, 10*2*2.5mm2, 12*2*2.5mm2, 14*2*2.5mm2 instrumentation cable

Conductor: Annealed copper or tinned copper

Insulation: PE,XLPE,PVC

Jacket: PVC,LSZH,FR

standards:TICW/06-2009 "computer and instruments cables"

instrumentation screened cables including collectively screened (CAM) and those individually screened and collectively screened (ICAM). These can be Polyethylene (PE), cross-linked Polyethylene (XLPE), Polyvinyl Chloride (PVC). They also generally have a PVC outer sheath or low smoke zero halogen(LSZH) sheathing for areas where smoke and acid gas emission would cause a serious problem in a fire situation.  BS5308 instrumentation cables, are also available armored with steel wire armour or steel tape, offering protection against mechanical stresses.



MODEL No. Description


Both general shielding   and individual shielding


DJYPVP The instrument cable with copper   conductor, polyethylene insulation, both copper wire braided individual   shielding and copper wire braided general shielding, PVC outer sheath


DJYP1VP1 The instrument cable with copper   conductor, polyethylene insulation, both composite copper - plastic tape   individual shielding and composite copper- plastic tape general shielding,   PVC outer sheath


DJYP2VP2 The instrument cable with copper   conductor, polyethylene insulation, both copper strip braided individual   shielding and copper strip braided general shielding, PVC outer sheath


DJYP3VP3 The instrument cable with copper   conductor, polyethylene insulation, both composite aluminum- plastic tape   individual shielding and composite aluminum- plastic tape general shielding ,   PVC outer sheath


DJYJPVP The instrument cable with copper   conductor, XLPE insulation, both copper wire braided individual shielding and   copper wire braided general shielding, PVC outer sheath


DJYJP1VP1 The instrument cable with copper   conductor, XLPE insulation, both composite copper- plastic individual   shielding and composite copper -plastic tape general shielding, PVC outer   sheath


DJYJP2VP2 The instrument cable with copper   conductor, XLPE insulation, both copper strip braided individual shielding   and copper strip braided general shielding, PVC outer sheath


DJYJP3VP3 The instrument cable with copper   conductor , XLPE insulation, both composite aluminum - plastic tape   individual shielding and composite aluminum - plastic tape general shielding,   PVC outer sheath


DJVPVP The instrument cable with copper   conductor , PVC insulation, both copper wire braided individual shielding and   copper wire braided general shielding, PVC outer sheath


DJVP1VP1 The instrument cable with copper   conductor , PVC insulation, both composite copper-plastic tape individual   shielding and composite copper - plastic tape general shielding, PVC outer   sheath


DJVP2VP2 The instrument cable with copper   conductor, PVC insulation, both copper strip braided individual shielding and   copper strip braided general shielding, PVC outer sheath


DJVP3VP3 The instrument cable with copper   conductor, PVC insulation, both aluminum- plastic tape individual shielding   and composite aluminum - plastic tape general shielding, PVC outer sheath

fire resistant twisted pair cable 2 core 2.5mm manufacturer features

1, Cable laying temperature with PVC , polyethylene insulation cable should not below 0℃ . Besides the cable laying temperature with XLPE insulation should not below -15℃

2, Regarding to the cable with PVC , polyethylene insulation, their conductor allowed long term operating temperature is 70 ℃ .When a short circuit

happened(The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 160℃

3 To the cable with XLPE insulation, the conductor allowed long term operating temperature is 90℃. When a short circuit happened (The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 250℃

4、The allowable bending radius of the cable: the cable with unarmored, should not be less than 6 times of the outer diameter of the cable. Cable with armoured or copper tape shielding shall not be less than 12 times of the outer diameter of the cable. And the flexible cable with shielding layer shall not be less than 6 times of the outer diameter of the cable

Electrical Performance
Form A
TEST ITEM UNIT TECHNICAL INDEX
PE/XLPE  PVC
insulation insulation 
insulation resistance (20℃) ≥ Between any wire and conductor MΩ·km 1000 25
Between   wire and the shielding 1 1


14 awg twisted pair cable Application:

This product is suitable for power generation, metallurgy, petrochemical and other industrial and mining enterprises electronic instrument systems. Automatic control system of signal transmission and instruments detection,instrument connection with multi - pair shielding anti - interference cable; It is used as signal transmission and connection of checking appliances of distribution system, computer system and automatic system of power - generating metallurgy petroling chemistry.


1.Instrument cable minimizes noise and signal interference,delievery clean  signal in harsh environment and general manufacturing operations.

2.Instrument cable have a maximun counductor temperature at 90 °c  and a low temperature rating of -40 °c.

3.the cable jacket is resistent to sunlight ,moistureand vapour penetration.

4.Instrument cable is avaiable in individually shielded pairs or triads with an overall shield construction in 300v and 600v.


Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.

We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.


Previous: 
Next: 
Get in touch
Xite Cable will be dedicated to provide the best service, continue to progress and to become a model for the industry and excellent brand.

Quick Links

Get in touch

     (+86)-029-86198018 / (+86)-138-9194-3607

   sales@xitecable.com 

     Workshop B5, Jingfa Chuangxin Industry Park, No. 36, Jingwei Middle Road, Jingwei New City, ETDZ, Xi'an Shaanxi, P.R.China.

©  2021 Shaanxi Xite Cable Co.,Ltd  All rights reserved. 丨 Sitemap.