Availability: | |
---|---|
PV1-F
XITE
8544492100
tinned copper
600/1000V
XLPE and LSZH
XLPE and LSZH
Unarmored
Low smoke without halogen, good cold, ultraviolet, ozone - resistant and weather - resistant. Flame retardant, cutting resistance and penetration resistance.
Construction:
1. Conductor - Class 5 tinned annealed stranded copper conductor
2. Insulation - Low smoke halogen-free electron-beam cross-linked compounds (XLPO)
3. Outer sheath - Low smoke halogen-free electron-beam cross-linked compounds(XLPO)
Cross Section:
Item: PV1-F Standard: UL/ TUV
Voltage: 1.0/1.5KV Conductor: Cu, Tinned copper
Material:XLPO/ XLPO Section: 1.5 mm²-95 mm²
Temperature characteristics:
Working temperature: -40ºC~90ºC
Max. temperature at conductor: 120ºC
Short Circuit temperature: 200ºC (at max.5sec)
Electrical Characteristics:
Rated Voltage:
AC U0/U:0.6/1kV
DC Max. : 1800V (conductor/conductor, non-earthed system)
Spark Test Voltage: 6000 V AC
5min Test Voltage: 6500V
Chemical Features:
Weather / UV Resistance
Resistance mineral oil
Color:
Insulation: Black or White or as customer's requirement
Outer sheath: Red or Black or as customer's requirement
Application:
Solar cables applies to flexible single-core cables (cords) for use at the DC-side of photovoltaic systems with a maximum permissible voltage of DC 1.8 kV (conductor/conductor, non-earthed system).The cables are suitable for use in safety class II. It is permitted to connect these cables as multiple-construction. The cables are intended to operate at ambient temperature until 90°C
Rated Voltage | 1000V AC |
Conductor Material | Tinned Copper |
Insulation and Jacket Material | Irradiation cross-linked polyolefin, Halogen-free |
Number of Conductors | single-core/ dual-core |
Cross Section | 1.5 mm2~95 mm2 |
The High Voltage Test | AC 6,5kV, or DC 1 5kV |
Working Temperature | -40℃~90℃ |
Max. Conductor Temperature | 120℃ |
Cross section (mm2) | Conductor Construction | Outer (mm) | Resistance Max. | Current Carring Capacity |
1*1.5 | 30/0.25 | 4.9 | 13.3 | 30 |
1*2.5 | 50/0.25 | 5.45 | 7.89 | 41 |
1*4 | 56/0.3 | 6.1 | 4.75 | 50 |
1*6 | 84/0.3 | 7.2 | 3.39 | 70 |
1*10 | 142/0.3 | 9 | 1.95 | 98 |
1*16 | 228/0.3 | 10.2 | 1.24 | 132 |
1*25 | 361/0.3 | 12 | 0.795 | 176 |
1*35 | 525/0.3 | 13.8 | 0.565 | 218 |
1*50 | 720/0.3 | 14.8 | 0.393 | 280 |
1*70 | 988/0.3 | 16.9 | 0.277 | 350 |
1*95 | 1349/0.3 | 18.7 | 0.21 | 410 |
1*120 | 1691/0.3 | 20.7 | 0.164 | 480 |
* Dual wall insulation protection
* Resistant to impact, tear and abrasion
* Very good resistance to oil , chemicals UV, water and oxygen
* Excellent flexibility & stripability: for fast and easy installation
* Halogen-free: low smoke emission and low toxicity during fire
* A life time : lasts up to 30 years even under tough conditions
* Suitable to common connector types
* TUV certification approved
Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.
We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.
Construction:
1. Conductor - Class 5 tinned annealed stranded copper conductor
2. Insulation - Low smoke halogen-free electron-beam cross-linked compounds (XLPO)
3. Outer sheath - Low smoke halogen-free electron-beam cross-linked compounds(XLPO)
Cross Section:
Item: PV1-F Standard: UL/ TUV
Voltage: 1.0/1.5KV Conductor: Cu, Tinned copper
Material:XLPO/ XLPO Section: 1.5 mm²-95 mm²
Temperature characteristics:
Working temperature: -40ºC~90ºC
Max. temperature at conductor: 120ºC
Short Circuit temperature: 200ºC (at max.5sec)
Electrical Characteristics:
Rated Voltage:
AC U0/U:0.6/1kV
DC Max. : 1800V (conductor/conductor, non-earthed system)
Spark Test Voltage: 6000 V AC
5min Test Voltage: 6500V
Chemical Features:
Weather / UV Resistance
Resistance mineral oil
Color:
Insulation: Black or White or as customer's requirement
Outer sheath: Red or Black or as customer's requirement
Application:
Solar cables applies to flexible single-core cables (cords) for use at the DC-side of photovoltaic systems with a maximum permissible voltage of DC 1.8 kV (conductor/conductor, non-earthed system).The cables are suitable for use in safety class II. It is permitted to connect these cables as multiple-construction. The cables are intended to operate at ambient temperature until 90°C
Rated Voltage | 1000V AC |
Conductor Material | Tinned Copper |
Insulation and Jacket Material | Irradiation cross-linked polyolefin, Halogen-free |
Number of Conductors | single-core/ dual-core |
Cross Section | 1.5 mm2~95 mm2 |
The High Voltage Test | AC 6,5kV, or DC 1 5kV |
Working Temperature | -40℃~90℃ |
Max. Conductor Temperature | 120℃ |
Cross section (mm2) | Conductor Construction | Outer (mm) | Resistance Max. | Current Carring Capacity |
1*1.5 | 30/0.25 | 4.9 | 13.3 | 30 |
1*2.5 | 50/0.25 | 5.45 | 7.89 | 41 |
1*4 | 56/0.3 | 6.1 | 4.75 | 50 |
1*6 | 84/0.3 | 7.2 | 3.39 | 70 |
1*10 | 142/0.3 | 9 | 1.95 | 98 |
1*16 | 228/0.3 | 10.2 | 1.24 | 132 |
1*25 | 361/0.3 | 12 | 0.795 | 176 |
1*35 | 525/0.3 | 13.8 | 0.565 | 218 |
1*50 | 720/0.3 | 14.8 | 0.393 | 280 |
1*70 | 988/0.3 | 16.9 | 0.277 | 350 |
1*95 | 1349/0.3 | 18.7 | 0.21 | 410 |
1*120 | 1691/0.3 | 20.7 | 0.164 | 480 |
* Dual wall insulation protection
* Resistant to impact, tear and abrasion
* Very good resistance to oil , chemicals UV, water and oxygen
* Excellent flexibility & stripability: for fast and easy installation
* Halogen-free: low smoke emission and low toxicity during fire
* A life time : lasts up to 30 years even under tough conditions
* Suitable to common connector types
* TUV certification approved
Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.
We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.
(+86)-029-86198018 / (+86)-138-9194-3607
sales@xitecable.com
Workshop B5, Jingfa Chuangxin Industry Park, No. 36, Jingwei Middle Road, Jingwei New City, ETDZ, Xi'an Shaanxi, P.R.China.