China Twisted Pairs 3X2X1.5mm2 XLPE Insulated Individual Screen Overall Shield ISOS LSZH Sheathed Instrumentation Cable pair 1.5mm2 Instrumentation Cable

300/500V China Twisted Pairs 3X2X1.5mm2 XLPE Insulated Individual Screen Overall Shield ISOS LSZH Sheathed Instrumentation Cable pair 1.5mm2 Instrumentation Cable
Availability:
  • DJYPV22,DJYVP22,DJYPVP22,DJYP1V22,DJYVP1-22,DJYP1VP1-22,DJYP2V-22,DJYVP2-22,DJYP2VP2-22,DJYP3V22,DJYVP3-22,DJYP3VP3-22,DJYJPV22,DJYJVP22,DJYJPVP22,DJYJP1V22,DJYJVP1-22,DJYJP1VP1-22,DJYJP2V22,DJYJVP2-2

  • XITE

  • 8544492100

  • Copper or tinned copper

  • 300/500V

  • XLPE or PVC or PE

  • PVC or FR or LSZH

  • Unarmored

  • Flame Retardant, Antiflaming, Fire resistance, LSZH

China Twisted Pairs 3X2X1.5mm2 XLPE Insulated Individual Screen Overall Shield ISOS LSZH Sheathed Instrumentation Cable pair 1.5mm2 Instrumentation Cable


overall screen cable-XITE different types of instrument cables-XITE

3 twisted pair shielded cable cost Introduction:

Instrumentation Cable

Size: 0.5mm2~2.5mm2

Conductor: Annealed or tinned copper

Insulation: PE,XLPE

Jacket: PVC,LSZH

Rated Temperature: 750℃,840℃,950℃

Rated Voltage: 600V

Nominal Size: 0.5mm2, 0.75mm2, 1.0mm2, 1.5mm2, 2.5mm2

Core: 2 core, 3 core

Pair: 1 pair, 2 pairs,3 pairs ,4 pairs ,5 pairs ,7 pairs ,8 pairs ,10 pairs ,12 pairs ,14 pairs,16 pairs ,19 pairs ,24 pairs ,27 pairs ,30 pairs, 37 pairs

Specification:1*2*1.5mm2, 2*2*1.5mm2, 3*2*1.5mm2, 4*2*1.5mm2, 5*2*1.5mm2, 7*2*1.5mm2, 8*2*1.5mm2, 10*2*1.5mm2, 12*2*1.5mm2, 14*2*1.5mm2 instrumentation cable

Conductor: Annealed copper or tinned copper

Insulation: PE,XLPE,PVC

Jacket: PVC,LSZH,FR

standards:TICW/06-2009 "computer and instruments cables"

instrumentation screened cables including collectively screened (CAM) and those individually screened and collectively screened (ICAM). These can be Polyethylene (PE), cross-linked Polyethylene (XLPE), Polyvinyl Chloride (PVC). They also generally have a PVC outer sheath or low smoke zero halogen(LSZH) sheathing for areas where smoke and acid gas emission would cause a serious problem in a fire situation.  BS5308 instrumentation cables, are also available armored with steel wire armour or steel tape, offering protection against mechanical stresses.



MODEL No. Description


Both general shielding   and individual shielding


DJYPVP The instrument cable with copper   conductor, polyethylene insulation, both copper wire braided individual   shielding and copper wire braided general shielding, PVC outer sheath


DJYP1VP1 The instrument cable with copper   conductor, polyethylene insulation, both composite copper - plastic tape   individual shielding and composite copper- plastic tape general shielding,   PVC outer sheath


DJYP2VP2 The instrument cable with copper   conductor, polyethylene insulation, both copper strip braided individual   shielding and copper strip braided general shielding, PVC outer sheath


DJYP3VP3 The instrument cable with copper   conductor, polyethylene insulation, both composite aluminum- plastic tape   individual shielding and composite aluminum- plastic tape general shielding ,   PVC outer sheath


DJYJPVP The instrument cable with copper   conductor, XLPE insulation, both copper wire braided individual shielding and   copper wire braided general shielding, PVC outer sheath


DJYJP1VP1 The instrument cable with copper   conductor, XLPE insulation, both composite copper- plastic individual   shielding and composite copper -plastic tape general shielding, PVC outer   sheath


DJYJP2VP2 The instrument cable with copper   conductor, XLPE insulation, both copper strip braided individual shielding   and copper strip braided general shielding, PVC outer sheath


DJYJP3VP3 The instrument cable with copper   conductor , XLPE insulation, both composite aluminum - plastic tape   individual shielding and composite aluminum - plastic tape general shielding,   PVC outer sheath


DJVPVP The instrument cable with copper   conductor , PVC insulation, both copper wire braided individual shielding and   copper wire braided general shielding, PVC outer sheath


DJVP1VP1 The instrument cable with copper   conductor , PVC insulation, both composite copper-plastic tape individual   shielding and composite copper - plastic tape general shielding, PVC outer   sheath


DJVP2VP2 The instrument cable with copper   conductor, PVC insulation, both copper strip braided individual shielding and   copper strip braided general shielding, PVC outer sheath


DJVP3VP3 The instrument cable with copper   conductor, PVC insulation, both aluminum- plastic tape individual shielding   and composite aluminum - plastic tape general shielding, PVC outer sheath

1.5mm pair twisted instrument cable manufacturer features

1, Cable laying temperature with PVC , polyethylene insulation cable should not below 0℃ . Besides the cable laying temperature with XLPE insulation should not below -15℃

2, Regarding to the cable with PVC , polyethylene insulation, their conductor allowed long term operating temperature is 70 ℃ .When a short circuit

happened(The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 160℃

3 To the cable with XLPE insulation, the conductor allowed long term operating temperature is 90℃. When a short circuit happened (The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 250℃

4、The allowable bending radius of the cable: the cable with unarmored, should not be less than 6 times of the outer diameter of the cable. Cable with armoured or copper tape shielding shall not be less than 12 times of the outer diameter of the cable. And the flexible cable with shielding layer shall not be less than 6 times of the outer diameter of the cable

Electrical Performance
Form A
TEST ITEM UNIT TECHNICAL INDEX
PE/XLPE  PVC
insulation insulation 
insulation resistance (20℃) ≥ Between any wire and conductor MΩ·km 1000 25
Between   wire and the shielding 1 1


double shielded twisted pair cable manufacturer Application:

Instrument cable has a broad range of uses,particularly in the petrochemical ,pulp,paper and sawmill,and other process industries.

Instrument cable design for wet and dry locations ,it is resistent to mechanical damage and corrosive chenicals ,and it is often employed in raceways,direct burial and control applications .


Instrumentation Cable Application: The armoured LSOH versions (Part 1 Type 2) are generally used when the risk of mechanical damage is increased. The galvanised steel wire armour provides excellent protection. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services, Also used for the interconnection of electrical equipment and instruments, the LSOH sheath can reduce toxic smoke and fume emission.


Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.

We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.


Previous: 
Next: 
Get in touch
Xite Cable will be dedicated to provide the best service, continue to progress and to become a model for the industry and excellent brand.

Quick Links

Get in touch

     (+86)-029-86198018 / (+86)-138-9194-3607

   sales@xitecable.com 

     Workshop B5, Jingfa Chuangxin Industry Park, No. 36, Jingwei Middle Road, Jingwei New City, ETDZ, Xi'an Shaanxi, P.R.China.

©  2021 Shaanxi Xite Cable Co.,Ltd  All rights reserved. 丨 Sitemap.