China Twisted Pairs 2X2X1.5mm2 XLPE Insulated Individual Screen Overall Shield ISOS LSZH Sheathed Instrumentation Cable 1.5mm2 Instrumentation Cable

China Twisted Pairs 2X2X1.5mm2 XLPE Insulated Individual Screen Overall Shield ISOS LSZH Sheathed Instrumentation Cable 1.5mm2 Instrumentation Cable
Availability:
  • DJYPV DJYP1V DJYP2V DJYP3V

  • XITE

  • 8544492100

  • Copper or tinned copper

  • 300/500V

  • XLPE or PVC or PE

  • PVC or FR or LSZH

  • Unarmored

  • Flame Retardant, Antiflaming, Fire resistance, LSZH

China Twisted Pairs 6X2X1.5mm2 XLPE Insulated Individual Screen Overall Shield ISOS LSZH Sheathed Instrumentation Cable 1.5mm2 Instrumentation Cable


overall screen cable-XITE different types of instrument cables-XITE

2x1.5mm pair twisted cable Introduction:

Nominal Size: 0.5mm2, 0.75mm2, 1.0mm2, 1.5mm2, 2.5mm2

Core: 2 core, 3 core

Pair: 1 pair, 2 pairs,3 pairs ,4 pairs ,5 pairs ,7 pairs ,8 pairs ,10 pairs ,12 pairs ,14 pairs,16 pairs ,19 pairs ,24 pairs ,27 pairs ,30 pairs, 37 pairs

Specification:1*2*1.5mm2, 2*2*1.5mm2, 3*2*1.5mm2, 4*2*1.5mm2, 5*2*1.5mm2, 7*2*1.5mm2, 8*2*1.5mm2, 10*2*1.5mm2, 12*2*1.5mm2, 14*2*1.5mm2 instrumentation cable

Conductor: Annealed copper or tinned copper

Insulation: PE,XLPE,PVC

Jacket: PVC,LSZH,FR

standards:TICW/06-2009 "computer and instruments cables"

instrumentation screened cables including collectively screened (CAM) and those individually screened and collectively screened (ICAM). These can be Polyethylene (PE), cross-linked Polyethylene (XLPE), Polyvinyl Chloride (PVC). They also generally have a PVC outer sheath or low smoke zero halogen(LSZH) sheathing for areas where smoke and acid gas emission would cause a serious problem in a fire situation.  BS5308 instrumentation cables, are also available armored with steel wire armour or steel tape, offering protection against mechanical stresses.



MODEL No. Description


Both general shielding   and individual shielding


DJYPVP The instrument cable with copper   conductor, polyethylene insulation, both copper wire braided individual   shielding and copper wire braided general shielding, PVC outer sheath


DJYP1VP1 The instrument cable with copper   conductor, polyethylene insulation, both composite copper - plastic tape   individual shielding and composite copper- plastic tape general shielding,   PVC outer sheath


DJYP2VP2 The instrument cable with copper   conductor, polyethylene insulation, both copper strip braided individual   shielding and copper strip braided general shielding, PVC outer sheath


DJYP3VP3 The instrument cable with copper   conductor, polyethylene insulation, both composite aluminum- plastic tape   individual shielding and composite aluminum- plastic tape general shielding ,   PVC outer sheath


DJYJPVP The instrument cable with copper   conductor, XLPE insulation, both copper wire braided individual shielding and   copper wire braided general shielding, PVC outer sheath


DJYJP1VP1 The instrument cable with copper   conductor, XLPE insulation, both composite copper- plastic individual   shielding and composite copper -plastic tape general shielding, PVC outer   sheath


DJYJP2VP2 The instrument cable with copper   conductor, XLPE insulation, both copper strip braided individual shielding   and copper strip braided general shielding, PVC outer sheath


DJYJP3VP3 The instrument cable with copper   conductor , XLPE insulation, both composite aluminum - plastic tape   individual shielding and composite aluminum - plastic tape general shielding,   PVC outer sheath


DJVPVP The instrument cable with copper   conductor , PVC insulation, both copper wire braided individual shielding and   copper wire braided general shielding, PVC outer sheath


DJVP1VP1 The instrument cable with copper   conductor , PVC insulation, both composite copper-plastic tape individual   shielding and composite copper - plastic tape general shielding, PVC outer   sheath


DJVP2VP2 The instrument cable with copper   conductor, PVC insulation, both copper strip braided individual shielding and   copper strip braided general shielding, PVC outer sheath


DJVP3VP3 The instrument cable with copper   conductor, PVC insulation, both aluminum- plastic tape individual shielding   and composite aluminum - plastic tape general shielding, PVC outer sheath

isos pair instrumentation cable price features

1, Cable laying temperature with PVC , polyethylene insulation cable should not below 0℃ . Besides the cable laying temperature with XLPE insulation should not below -15℃

2, Regarding to the cable with PVC , polyethylene insulation, their conductor allowed long term operating temperature is 70 ℃ .When a short circuit

happened(The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 160℃

3 To the cable with XLPE insulation, the conductor allowed long term operating temperature is 90℃. When a short circuit happened (The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 250℃

4、The allowable bending radius of the cable: the cable with unarmored, should not be less than 6 times of the outer diameter of the cable. Cable with armoured or copper tape shielding shall not be less than 12 times of the outer diameter of the cable. And the flexible cable with shielding layer shall not be less than 6 times of the outer diameter of the cable

Electrical Performance
Form A
TEST ITEM UNIT TECHNICAL INDEX
PE/XLPE  PVC
insulation insulation 
insulation resistance (20℃) ≥ Between any wire and conductor MΩ·km 1000 25
Between   wire and the shielding 1 1


multi pair instrument cable price Application:

Instrument cable has a broad range of uses,particularly in the petrochemical ,pulp,paper and sawmill,and other process industries.

Instrument cable design for wet and dry locations ,it is resistent to mechanical damage and corrosive chenicals ,and it is often employed in raceways,direct burial and control applications .


Please note that the above these cables could make to Antiflaming power cable, Fire resistance power cable, LSZH power cable in rated voltage 0.6/1 KV, PVC or XLPE insulated, PVC outer sheath.


The feature of the Antiflaming power cable: This cable is hard to be on fire, when it happens, the extend  fire point just be limited to a certain range. It is applicable to power stations, subways, tunnels, high-rise buildings, large industrial and mining enterprises, oil fields, coal mines and other places with high density of cable laying

The feature of the Fire resistance power cable: This cable can not only transmit power under normal working conditions, but also when the fire or the combustion happens, can still maintain a certain time of normal operation . It is suitable for nuclear power plant, subway, tunnel, high-rise building and other places related to fire safety and fire rescue

The feature of the LSZH power cable: This cable not only has the flame retardant performance, but also has low smoke and harmless (less toxicity and corrosion), suitable for the cable flame retardant, smoke density, toxicity index and other places with special requirements, such as subway, tunnel, nuclear power plant


Flame retardant grade: ZC, ZB, ZA (IA)


Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.

We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.


Previous: 
Next: 
Get in touch
Xite Cable will be dedicated to provide the best service, continue to progress and to become a model for the industry and excellent brand.

Quick Links

Get in touch

     (+86)-029-86198018 / (+86)-138-9194-3607

   sales@xitecable.com 

     Workshop B5, Jingfa Chuangxin Industry Park, No. 36, Jingwei Middle Road, Jingwei New City, ETDZ, Xi'an Shaanxi, P.R.China.

©  2021 Shaanxi Xite Cable Co.,Ltd  All rights reserved. 丨 Sitemap.