Availability: | |
---|---|
DJYPV DJYP1V DJYP2V DJYP3V DJYJPV DJYJP1V DJYJP2V DJYJP3V DJVPV DJVP1V DJVP2V DJVP3V
XITE
8544492100
Copper
450/750V
XLPE or PVC or PE
PVC or FR or LSZH
Unarmored
Flame Retardant, Antiflaming, Fire resistance, LSZH
Nominal Size: 0.5mm2,0.75mm2, 1.0mm2, 1.5mm2, 2.5mm2
Core: 2 core, 3 core
Pair: 1 pair, 2 pairs,3 pairs ,4 pairs ,5 pairs ,7 pairs ,8 pairs ,10 pairs ,12 pairs ,14 pairs,16 pairs ,19 pairs ,24 pairs ,27 pairs ,30 pairs, 37 pairs
Conductor: Annealed copper or tinned copper
Insulation: PE,XLPE,PVC
Jacket: PVC,LSZH,FR
standards:TICW/06-2009 "computer and instruments cables"
instrumentation screened cables including collectively screened (CAM) and those individually screened and collectively screened (ICAM). These can be Polyethylene (PE), cross-linked Polyethylene (XLPE), Polyvinyl Chloride (PVC). They also generally have a PVC outer sheath or low smoke zero halogen(LSZH) sheathing for areas where smoke and acid gas emission would cause a serious problem in a fire situation. BS5308 instrumentation cables, are also available armored with steel wire armour or steel tape, offering protection against mechanical stresses.
MODEL No. | Description |
Individual shielding | |
DJYPV | The instrument cable with copper conductor, polyethylene insulation, copper wire braided individual shielding, PVC outer sheath |
DJYP1V | The instrument cable with copper conductor, polyethylene insulation, composite copper-plastic tape individual shielding, PVC outer sheath |
DJYP2V | The instrument cable with copper conductor, polyethylene insulation, copper strip individual shielding, PVC outer sheath |
DJYP3V | The instrument cable with copper conductor, polyethylene insulation, composite aluminum-plastic tape individual shielding, PVC outer sheath |
DJYJPV | The instrument cable with copper conductor, XLPE insulation, copper wire braided individual shielding, PVC outer sheath |
DJYJP1V | The instrument cable with copper conductor, XLPE insulation, composite copper-plastic tape individual shielding, PVC outer sheath |
DJYJP2V | The instrument cable with copper conductor, XLPE insulation, copper strip individual shielding, PVC outer sheath |
DJYJP3V | The instrument cable with copper conductor, XLPE insulation, composite aluminum-plastic tape individual shielding, PVC outer sheath |
DJVPV | The instrument cable with copper conductor, PVC insulation, copper wire braided individual shielding, PVC outer sheath |
DJVP1V | The instrument cable with copper conductor, PVC insulation, composite copper-plastic tape shielding, PVC outer sheath |
DJVP2V | The instrument cable with copper conductor, PVC insulation, copper tape individual shielding, PVC outer sheath |
DJVP3V | The instrument cable with copper conductor, PVC insulation, composite aluminum-plastic tape individual shielding, PVC outer sheath |
1, Cable laying temperature with PVC , polyethylene insulation cable should not below 0℃ . Besides the cable laying temperature with XLPE insulation should not below -15℃
2, Regarding to the cable with PVC , polyethylene insulation, their conductor allowed long term operating temperature is 70 ℃ .When a short circuit
happened(The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 160℃
3 To the cable with XLPE insulation, the conductor allowed long term operating temperature is 90℃. When a short circuit happened (The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 250℃
4、The allowable bending radius of the cable: the cable with unarmored, should not be less than 6 times of the outer diameter of the cable. Cable with armoured or copper tape shielding shall not be less than 12 times of the outer diameter of the cable. And the flexible cable with shielding layer shall not be less than 6 times of the outer diameter of the cable
Electrical Performance | ||||
Form A | ||||
TEST ITEM | UNIT | TECHNICAL INDEX | ||
PE/XLPE | PVC | |||
insulation | insulation | |||
insulation resistance (20℃) ≥ | Between any wire and conductor | MΩ·km | 1000 | 25 |
Between wire and the shielding | 1 | 1 |
This product is suitable for power generation, metallurgy, petrochemical and other industrial and mining enterprises electronic instrument systems. Automatic control system of signal transmission and instruments detection, instrument connection with multi - pair shielding anti - interference cable
We supply a wide range of instrumentation cables suitable for an even wider range of applications across industries where manufacturing and processing operations are controlled and measured by electronic means.
For optimal performance, these interconnection cables have to be reliable, robust and offer shielded protection, whether an overall screen or individually and collectively screened cable, to resist electromagnetic interference.
Our instrumentation cable products with flexible copper conductors comply with Chin Standard and BS5308 standard instrumentation cables to meet their applications' specific requirements for industries including oil, gas & petrochemical, automation and process control, and marine & offshore.
Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.
We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.
Nominal Size: 0.5mm2,0.75mm2, 1.0mm2, 1.5mm2, 2.5mm2
Core: 2 core, 3 core
Pair: 1 pair, 2 pairs,3 pairs ,4 pairs ,5 pairs ,7 pairs ,8 pairs ,10 pairs ,12 pairs ,14 pairs,16 pairs ,19 pairs ,24 pairs ,27 pairs ,30 pairs, 37 pairs
Conductor: Annealed copper or tinned copper
Insulation: PE,XLPE,PVC
Jacket: PVC,LSZH,FR
standards:TICW/06-2009 "computer and instruments cables"
instrumentation screened cables including collectively screened (CAM) and those individually screened and collectively screened (ICAM). These can be Polyethylene (PE), cross-linked Polyethylene (XLPE), Polyvinyl Chloride (PVC). They also generally have a PVC outer sheath or low smoke zero halogen(LSZH) sheathing for areas where smoke and acid gas emission would cause a serious problem in a fire situation. BS5308 instrumentation cables, are also available armored with steel wire armour or steel tape, offering protection against mechanical stresses.
MODEL No. | Description |
Individual shielding | |
DJYPV | The instrument cable with copper conductor, polyethylene insulation, copper wire braided individual shielding, PVC outer sheath |
DJYP1V | The instrument cable with copper conductor, polyethylene insulation, composite copper-plastic tape individual shielding, PVC outer sheath |
DJYP2V | The instrument cable with copper conductor, polyethylene insulation, copper strip individual shielding, PVC outer sheath |
DJYP3V | The instrument cable with copper conductor, polyethylene insulation, composite aluminum-plastic tape individual shielding, PVC outer sheath |
DJYJPV | The instrument cable with copper conductor, XLPE insulation, copper wire braided individual shielding, PVC outer sheath |
DJYJP1V | The instrument cable with copper conductor, XLPE insulation, composite copper-plastic tape individual shielding, PVC outer sheath |
DJYJP2V | The instrument cable with copper conductor, XLPE insulation, copper strip individual shielding, PVC outer sheath |
DJYJP3V | The instrument cable with copper conductor, XLPE insulation, composite aluminum-plastic tape individual shielding, PVC outer sheath |
DJVPV | The instrument cable with copper conductor, PVC insulation, copper wire braided individual shielding, PVC outer sheath |
DJVP1V | The instrument cable with copper conductor, PVC insulation, composite copper-plastic tape shielding, PVC outer sheath |
DJVP2V | The instrument cable with copper conductor, PVC insulation, copper tape individual shielding, PVC outer sheath |
DJVP3V | The instrument cable with copper conductor, PVC insulation, composite aluminum-plastic tape individual shielding, PVC outer sheath |
1, Cable laying temperature with PVC , polyethylene insulation cable should not below 0℃ . Besides the cable laying temperature with XLPE insulation should not below -15℃
2, Regarding to the cable with PVC , polyethylene insulation, their conductor allowed long term operating temperature is 70 ℃ .When a short circuit
happened(The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 160℃
3 To the cable with XLPE insulation, the conductor allowed long term operating temperature is 90℃. When a short circuit happened (The maximum duration is less than 5 seconds), The conductor allowed maximum operating temperature should be 250℃
4、The allowable bending radius of the cable: the cable with unarmored, should not be less than 6 times of the outer diameter of the cable. Cable with armoured or copper tape shielding shall not be less than 12 times of the outer diameter of the cable. And the flexible cable with shielding layer shall not be less than 6 times of the outer diameter of the cable
Electrical Performance | ||||
Form A | ||||
TEST ITEM | UNIT | TECHNICAL INDEX | ||
PE/XLPE | PVC | |||
insulation | insulation | |||
insulation resistance (20℃) ≥ | Between any wire and conductor | MΩ·km | 1000 | 25 |
Between wire and the shielding | 1 | 1 |
This product is suitable for power generation, metallurgy, petrochemical and other industrial and mining enterprises electronic instrument systems. Automatic control system of signal transmission and instruments detection, instrument connection with multi - pair shielding anti - interference cable
We supply a wide range of instrumentation cables suitable for an even wider range of applications across industries where manufacturing and processing operations are controlled and measured by electronic means.
For optimal performance, these interconnection cables have to be reliable, robust and offer shielded protection, whether an overall screen or individually and collectively screened cable, to resist electromagnetic interference.
Our instrumentation cable products with flexible copper conductors comply with Chin Standard and BS5308 standard instrumentation cables to meet their applications' specific requirements for industries including oil, gas & petrochemical, automation and process control, and marine & offshore.
Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.
We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.
(+86)-029-86198018 / (+86)-138-9194-3607
sales@xitecable.com ; cathy@xitecable.com
Workshop B5, Jingfa Chuangxin Industry Park, No. 36, Jingwei Middle Road, Jingwei New City, ETDZ, Xi'an Shaanxi, P.R.China.