Availability: | |
---|---|
PV,PV1-F
XITE
8544492100
flexible tinned copper
600/1000V
XLPE or XLPO or halogen free
LSZH
Unarmored
Low smoke without halogen, good cold, ultraviolet, ozone - resistant and weather - resistant. Flame retardant, cutting resistance and penetration resistance.
Conductor: tinned copper wire
Nominal Section: 2.5mm2, 4mm2, 6mm2, 8mm 10mm2, 16mm2 PV1 - F
18, 16 and 14, 12, 10, 8, 6, 4, 2mm2 PV wire
Insulation: > 0.5mm thick with low smoke and halogen material, and meet the specified limit of the customer.
Sheath: low smoke and halogen free material thickness > 0.5mm.
parameters
Ambient temperature: - 40 ℃ ~ + 90 ℃
The highest temperature of conductor: 120 ℃ (allow 5 s in short circuit temperature 200 ℃)
Limited voltage: AC0.6/1kv
Conductor: tinned copper wire
Core No.: 2 core, twin core
Nominal Section: 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2 PV1 - F
18, 16 and 14, 12, 10, 8, 6, 4, 2mm2 PV wire
Insulation: > 0.5mm thick with low smoke and halogen material, and meet the specified limit of the customer.
Sheath: low smoke and halogen free material thickness > 0.5mm.
parameters
Ambient temperature: - 40 ℃ ~ + 90 ℃
The highest temperature of conductor: 120 ℃ (allow 5 s in short circuit temperature 200 ℃)
Limited voltage: AC0.6/1kv
Cross section (mm2) | Conductor Construction | Outer (mm) | Resistance Max. | Current Carring Capacity |
2 x 2.5 | 50/0.25 | 9.2 ± 0.2 | 7.98 | 41 |
2 x 4 | 56/0.3 | 12.0 ± 0.2 | 4.75 | 50 |
2 x 6 | 84/0.3 | 13.5 ± 0.2 | 3.39 | 70 |
2 x 10 | 142/0.3 | 17.6 ± 0.2 | 1.95 | 98 |
2 x 16 | 228/0.3 | 19.8 ± 0.2 | 1.24 | 132 |
Cross section (mm2) | Conductor Construction | Outer (mm) | Resistance Max. | Current Carring Capacity |
1*1.5 | 30/0.25 | 4.9 | 13.3 | 30 |
1*2.5 | 50/0.25 | 5.45 | 7.89 | 41 |
1*4 | 56/0.3 | 6.1 | 4.75 | 50 |
1*6 | 84/0.3 | 7.2 | 3.39 | 70 |
1*10 | 142/0.3 | 9 | 1.95 | 98 |
1*16 | 228/0.3 | 10.2 | 1.24 | 132 |
1*25 | 361/0.3 | 12 | 0.795 | 176 |
1*35 | 525/0.3 | 13.8 | 0.565 | 218 |
1*50 | 720/0.3 | 14.8 | 0.393 | 280 |
1*70 | 988/0.3 | 16.9 | 0.277 | 350 |
1*95 | 1349/0.3 | 18.7 | 0.21 | 410 |
1*120 | 1691/0.3 | 20.7 | 0.164 | 480 |
The solar cable is also called PV cable, which connects photovoltaic modules and inverters, and the cable is used in 600/1000V AC 1500V DC. Solar energy systems are often used under harsh environmental conditions, such as high temperature and ultraviolet radiation. Therefore, the solar cable is different from ordinary cables. In comparison, PV cables have the characteristics of temperature resistance, cold resistance, oil resistance, acid and alkali salt resistance, UV resistance, flame retardancy, and environmental protection.
Rated Voltage | 1000V AC |
Conductor Material | Tinned Copper |
Insulation and Jacket Material | Irradiation cross-linked polyolefin, Halogen-free |
Number of Conductors | single-core/ twin-core |
Cross Section | 1.5 mm2~95 mm2 |
The High Voltage Test | AC 6,5kV, or DC 1 5kV |
Working Temperature | -40℃~90℃ |
Max. Conductor Temperature | 120℃ |
Low smoke without halogen, good cold, ultraviolet, ozone - resistant and weather - resistant.
Flame retardant, cutting resistance and penetration resistance.
With 150 ℃ photovoltaic cable radiation as insulation materials, halogen free flame retardant is halogen-free, non-toxic modified polyethylene thin hengjing resin as the main raw material, add halogen-free, non-toxic, flame retardant, heat stabilizer, eliminate smoke agent, preservative, such as fertilizer, does not contain halogen, heavy metals, phosphorus. It conforms to ROHS, and the insulation resistance is small after immersion.
1. The dc resistance: the finished cable at 20 ℃ conductive wire core dc resistance is not greater than 5.09 Ω/km
2. The insulation resistance: the finished insulation resistance of cable at 20 ℃ should not less than 1014 Ω. Cm, finished cable insulation resistance at 90 ℃ is not less than 1011 Ω. Cm
3. The sheath surface resistance: resistance of the finished cable sheath surface should be not less than 109 Ω
Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.
We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.
Conductor: tinned copper wire
Nominal Section: 2.5mm2, 4mm2, 6mm2, 8mm 10mm2, 16mm2 PV1 - F
18, 16 and 14, 12, 10, 8, 6, 4, 2mm2 PV wire
Insulation: > 0.5mm thick with low smoke and halogen material, and meet the specified limit of the customer.
Sheath: low smoke and halogen free material thickness > 0.5mm.
parameters
Ambient temperature: - 40 ℃ ~ + 90 ℃
The highest temperature of conductor: 120 ℃ (allow 5 s in short circuit temperature 200 ℃)
Limited voltage: AC0.6/1kv
Conductor: tinned copper wire
Core No.: 2 core, twin core
Nominal Section: 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2 PV1 - F
18, 16 and 14, 12, 10, 8, 6, 4, 2mm2 PV wire
Insulation: > 0.5mm thick with low smoke and halogen material, and meet the specified limit of the customer.
Sheath: low smoke and halogen free material thickness > 0.5mm.
parameters
Ambient temperature: - 40 ℃ ~ + 90 ℃
The highest temperature of conductor: 120 ℃ (allow 5 s in short circuit temperature 200 ℃)
Limited voltage: AC0.6/1kv
Cross section (mm2) | Conductor Construction | Outer (mm) | Resistance Max. | Current Carring Capacity |
2 x 2.5 | 50/0.25 | 9.2 ± 0.2 | 7.98 | 41 |
2 x 4 | 56/0.3 | 12.0 ± 0.2 | 4.75 | 50 |
2 x 6 | 84/0.3 | 13.5 ± 0.2 | 3.39 | 70 |
2 x 10 | 142/0.3 | 17.6 ± 0.2 | 1.95 | 98 |
2 x 16 | 228/0.3 | 19.8 ± 0.2 | 1.24 | 132 |
Cross section (mm2) | Conductor Construction | Outer (mm) | Resistance Max. | Current Carring Capacity |
1*1.5 | 30/0.25 | 4.9 | 13.3 | 30 |
1*2.5 | 50/0.25 | 5.45 | 7.89 | 41 |
1*4 | 56/0.3 | 6.1 | 4.75 | 50 |
1*6 | 84/0.3 | 7.2 | 3.39 | 70 |
1*10 | 142/0.3 | 9 | 1.95 | 98 |
1*16 | 228/0.3 | 10.2 | 1.24 | 132 |
1*25 | 361/0.3 | 12 | 0.795 | 176 |
1*35 | 525/0.3 | 13.8 | 0.565 | 218 |
1*50 | 720/0.3 | 14.8 | 0.393 | 280 |
1*70 | 988/0.3 | 16.9 | 0.277 | 350 |
1*95 | 1349/0.3 | 18.7 | 0.21 | 410 |
1*120 | 1691/0.3 | 20.7 | 0.164 | 480 |
The solar cable is also called PV cable, which connects photovoltaic modules and inverters, and the cable is used in 600/1000V AC 1500V DC. Solar energy systems are often used under harsh environmental conditions, such as high temperature and ultraviolet radiation. Therefore, the solar cable is different from ordinary cables. In comparison, PV cables have the characteristics of temperature resistance, cold resistance, oil resistance, acid and alkali salt resistance, UV resistance, flame retardancy, and environmental protection.
Rated Voltage | 1000V AC |
Conductor Material | Tinned Copper |
Insulation and Jacket Material | Irradiation cross-linked polyolefin, Halogen-free |
Number of Conductors | single-core/ twin-core |
Cross Section | 1.5 mm2~95 mm2 |
The High Voltage Test | AC 6,5kV, or DC 1 5kV |
Working Temperature | -40℃~90℃ |
Max. Conductor Temperature | 120℃ |
Low smoke without halogen, good cold, ultraviolet, ozone - resistant and weather - resistant.
Flame retardant, cutting resistance and penetration resistance.
With 150 ℃ photovoltaic cable radiation as insulation materials, halogen free flame retardant is halogen-free, non-toxic modified polyethylene thin hengjing resin as the main raw material, add halogen-free, non-toxic, flame retardant, heat stabilizer, eliminate smoke agent, preservative, such as fertilizer, does not contain halogen, heavy metals, phosphorus. It conforms to ROHS, and the insulation resistance is small after immersion.
1. The dc resistance: the finished cable at 20 ℃ conductive wire core dc resistance is not greater than 5.09 Ω/km
2. The insulation resistance: the finished insulation resistance of cable at 20 ℃ should not less than 1014 Ω. Cm, finished cable insulation resistance at 90 ℃ is not less than 1011 Ω. Cm
3. The sheath surface resistance: resistance of the finished cable sheath surface should be not less than 109 Ω
Cables with Low smoke zero halogen, fire resistance, flame-retardant is our advantage, we have National Patent Certificate on it.
We have CCC and ISO9001 certificate, we can accept ODM, OEM and also can accept personal customized.
(+86)-029-86198018 / (+86)-138-9194-3607
sales@xitecable.com ; cathy@xitecable.com
Workshop B5, Jingfa Chuangxin Industry Park, No. 36, Jingwei Middle Road, Jingwei New City, ETDZ, Xi'an Shaanxi, P.R.China.